Calculation procedures

Source version current through Oct 31, 2022

Later State Register activity may affect this section.

Source details
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Oct 31, 2022
Text saved
Sep 13, 2026
Publisher current-through date
Oct 31, 2022
Source captured
Sep 13, 2026
Stored text comparison
Matches the captured source text
(a)For existing buildings for which a comprehensive lighting energy analysis was conducted prior to September 1, 1980, the building lighting power budget and building lighting load shall be the figures calculated in the course of such comprehensive lighting energy analysis.
(b)For all other existing buildings, the building lighting power budget and the building lighting load shall be calculated in accordance with the following procedures:
(1)calculate the building lighting power budget by summing the lighting power budgets determined for each space in the existing building, and multiplying this sum by 1.1. The lighting power budget for each space shall be calculated in accordance with the following procedure:
(i)determine the primary space use, and select the appropriate space use factor from the Space Use Table contained in subdivision (c) of this section (Table 1.1). Do not calculate a lighting power budget for any space which is not listed in the Space Use Table;
(ii)determine the predominant type of fixture in the space, other than specialized lighting fixtures. Select a fixture factor of either 1.0 if the predominant type of fixture uses fluorescent lamps, or 1.4 if the predominant type of fixture uses incandescent or mercury vapor lamps. When a space contains only specialized lighting fixtures, do not calculate a lighting power budget for such space;
(iii)determine length, width, and area of the space, and the fixture height (the distance between the bottom of the fixture and the floor);
(iv)select the lighting power density corresponding to the length and width of the space and the fixture height from the Space Power Table contained in subdivision (d) of this section (Table 1.2); and
(v)multiply the space use factor selected under subparagraph (i) of this paragraph, times the fixture factor selected under subparagraph (ii), times the area determined under subparagraph (iii), times the lighting power density selected under subparagraph (iv). The product is the lighting power budget for that space; and
(2)calculate the building lighting load by summing the lighting load for each space for which a lighting power budget has been calculated. The lighting load for each space shall be calculated by summing the wattage of all lamps installed in permanently mounted fixtures in such space, other than specialized lighting fixtures. The lighting load shall include the ballast loss for fluorescent and mercury vapor fixtures.
(c)TABLE 1.1—SPACE USE TABLE.
SPACE USE SPACE USE FACTOR
A.General Building Spaces
1.Lobbys, Waiting Rooms0.5
2.Corridors0.5
3.Stairs0.4
4.Toilet Rooms0.6
5.Mechanical Space0.3
6.Meeting Rooms ( e.g., court room, jury room, conference room)0.6
7.Vestibule and Entry Ways0.9
B.Office Spaces
1.General Offices1.0
2.Specialized Office Space ( e.g., bookkeeping, accounting, drafting, etc.)1.5
3.Computer Rooms1.2
C.Retail Spaces
1.Merchandising Areas1.0
2.General Circulation Areas0.6
D.Specialized Spaces
1.Book Stacks0.8
2.Reading Areas1.0
3.Counterwork Areas ( e.g., checkout counter, cashier, bank tellers, security control checkpoint, nurses station, etc.)1.0
4.Stockrooms ( e.g., shipping and receiving, sorting space)0.8
5.Lecture Halls0.6
6.Classrooms, including laboratories and art rooms1.0
7.Locker Rooms, including dressing rooms and shower rooms0.5
8.Warehouse Spaces0.6
9.Display, Exhibit and Demonstration Spaces1.2
10.Food Preparation Areas0.6
11.Food Serving Areas1.0
12.Gymnasiums, Indoor Recreation1.0
13.Public Assembly Spaces ( e.g., spectator seating, audience seating, congregational space0.6
(d)TABLE 1.2—SPACE POWER TABLE.
ROOM DIMENSIONS*(in feet)FIXTURE MOUNTING HEIGHT (in feet)
WidthLength88.599.51010.5111213141520 & higher
8102.83.03.23.43.63.84.04.04.04.04.04.0
122.62.83.03.23.43.63.84.04.04.04.04.0
142.62.82.83.03.03.43.64.04.04.04.04.0
162.42.62.82.83.03.23.63.84.04.04.04.0
182.42.62.82.83.03.03.43.64.04.04.04.0
20 & larger2.42.62.62.82.83.03.43.63.84.04.04.0
10102.62.82.83.03.23.43.64.04.04.04.04.0
122.42.62.82.83.03.23.43.64.04.04.04.0
142.42.42.62.82.83.03.23.43.84.04.04.0
162.42.42.62.82.82.83.03.23.64.04.04.0
182.42.42.62.62.82.82.83.23.43.84.04.0
20 & larger2.42.42.42.62.62.82.83.03.43.64.04.0
12122.42.42.62.82.82.83.03.43.64.04.04.0
142.42.42.42.62.82.82.83.23.43.84.04.0
162.22.42.42.42.62.82.83.03.43.63.84.0
182.22.22.42.42.42.62.82.83.23.43.63.8
202.02.22.42.42.42.62.62.83.03.23.63.8
222.02.22.22.42.42.42.62.83.03.23.43.6
242.02.22.22.42.42.42.62.82.83.03.43.6
262.02.02.22.42.42.42.42.82.83.03.23.6
282.02.02.22.42.42.42.42.62.83.03.23.4
30 & larger2.02.02.22.22.42.42.42.62.83.03.23.4
14142.22.42.42.42.62.62.83.03.23.43.84.0
162.02.22.42.42.42.62.62.83.03.23.64.0
182.02.22.22.42.42.42.62.82.83.23.43.8
202.02.02.22.32.42.42.42.82.83.03.23.6
222.02.02.22.22.42.42.42.62.82.83.23.6
242.02.02.02.22.22.42.42.62.82.83.03.4
262.02.02.02.22.22.42.42.42.82.83.03.4
282.02.02.02.22.22.42.42.42.62.82.83.2
30 & larger2.02.02.02.02.22.22.42.42.62.82.83.2
16162.02.22.22.42.42.42.62.82.83.03.43.8
182.02.02.22.22.42.42.42.62.83.03.23.6
202.02.02.22.22.22.42.42.62.82.83.03.6
222.02.02.22.22.22.42.42.42.62.82.83.4
242.02.02.02.02.22.22.42.42.62.62.83.4
262.02.02.02.02.22.22.42.42.62.62.83.2
281.82.02.02.02.02.22.22.42.42.62.83.2
30 & larger1.82.02.02.02.02.22.22.42.42.62.83.2
18182.02.02.22.22.42.42.62.82.82.83.03.4
202.02.02.02.22.22.42.42.62.62.82.83.4
222.02.02.02.22.22.42.42.62.62.82.83.4
241.82.02.02.02.22.22.42.42.42.62.83.2
261.82.02.02.02.22.22.42.42.42.62.83.2
281.82.02.02.02.02.22.42.42.42.62.63.2
30 & larger1.82.02.02.02.02.22.22.42.42.42.63.0

*

Dimensions which fall between those listed dimensions should be rounded to the closest dimension. When a dimension falls exactly at the midpoint, the closest dimension shall be the larger dimension.

(e)TABLE 1.3—SPACE POWER TABLE.
ROOM DIMENSIONS*(in feet)FIXTURE MOUNTING HEIGHT (in feet)
WidthLength88.599.51010.5111213141520 & higher
20202.02.02.02.02.22.22.42.42.62.82.83.2
222.02.02.02.02.22.22.22.42.42.62.83.2
241.82.02.02.02.02.02.22.42.42.42.63.0
261.81.82.02.02.02.02.22.22.42.42.63.0
281.81.82.02.02.02.02.02.22.42.42.63.0
30 & larger1.81.81.82.02.02.02.02.22.42.42.63.0
22221.81.82.02.02.02.02.22.42.42.42.62.8
241.81.82.02.02.02.02.02.22.42.42.62.8
261.81.82.02.02.02.02.02.22.42.42.42.8
281.81.81.82.02.02.02.02.22.42.42.42.6
30 & larger1.81.81.82.02.02.02.02.22.42.42.42.6
24241.81.81.82.02.02.02.02.22.42.42.42.6
261.81.81.82.02.02.02.02.22.42.42.42.6
281.81.81.81.82.02.02.02.02.22.42.42.6
30 & larger1.81.81.81.82.02.02.02.02.22.42.42.6
26261.81.81.81.82.02.02.02.02.22.42.42.6
281.81.81.81.82.02.02.02.02.22.22.42.6
30 & larger1.81.81.81.81.82.02.02.02.22.22.42.6
28281.81.81.81.81.82.02.02.02.22.22.42.4
30 & larger1.81.81.81.81.82.02.02.02.02.22.42.4
30301.81.81.81.81.81.82.02.02.02.22.22.4
401.81.81.81.81.81.82.02.02.02.02.22.4
501.81.81.81.81.81.81.81.82.02.02.02.4
60 & larger1.81.81.81.81.81.81.81.81.82.02.02.2
40401.81.81.81.81.81.81.81.82.02.02.02.2
501.81.81.81.81.81.81.81.82.02.02.02.2
60 & larger1.81.81.81.81.81.81.81.81.81.81.82.2
50501.81.81.81.81.81.81.81.81.81.81.82.0
60 & larger1.81.81.81.81.81.81.81.81.81.81.82.0
60 larger60 & larger1.81.81.81.81.81.81.81.81.81.81.82.0

*

Dimensions which fall between those listed dimensions should be rounded to the closest dimension. When a dimension falls exactly at the midpoint, the closest dimension shall be the larger dimension.