9 NYCRR 1610.0 - Foreword
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
9 NYCRR 1610.1 - The site
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Sites for projects are selected with regard to municipal plans, where such exist. They are to be developed “in conformity with a plan or undertaking for the clearance, replanning, reconstruction or rehabilitation of a substandard and insanitary area or areas and for recreational and other facilities incidental or appurtenant thereto”.
The project shall comply with all required zoning.
Column (A)—:
Minimum distances between parallel longitudinal walls.
Column (B)—:
Minimum distances between longitudinal walls and end walls; two end walls; corners of adjacent buildings; and between longitudinal walls and interior lot lines.
| Story height | A | B |
|---|---|---|
| 1 | 46 | 31 |
| 2 | 50 | 34 |
| 3 | 54 | 36 |
| 4 | 58 | 39 |
| 5 | 62 | 41 |
| 6 | 66 | 44 |
| 7 | 70 | 47 |
| 8 | 74 | 50 |
| 9 | 78 | 52 |
| 10 | 82 | 55 |
| 11 | 86 | 58 |
| 12 | 90 | 60 |
| 13 | 94 | 63 |
| 14 | 98 | 66 |
| 15 | 102 | 68 |
| 16 | 106 | 71 |
| 17 | 110 | 74 |
| 18 | 114 | 76 |
| 19 | 118 | 79 |
| 20 | 122 | 82 |
| 21 | 126 | 84 |
9 NYCRR 1610.2 - Non-dwelling facilities
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Provide individual tenant storage space within each apartment or cellar. Also, provide a centrally located tool storage space and a small general store room. Provide outside drying facilities (approximately 45 square feet per dwelling unit).
Provide, under management control, central storage spaces for perambulators and wheel toys; also, one or more central laundries. All of these spaces shall be accessible from the outside via a ramp. The size of the laundry shall be based upon the number of fixtures. Provide approximately one washing machine for each 60 families in a project with more than 500 apartments; one washing machine for each 35 families in smaller projects. The laundry shall contain provisions for laundry trays, extractors and mechanical dryers. Provide toilet facilities accessible to such laundry for the use of the tenants; also adjacent small storage closet.
The following minimum areas for management offices and maintenance and repair spaces shall be provided:
| Number of Dwelling Units in Project | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Under | 100 | 150 | 250 | 350 | 500 | 750 | 1,000 | Over | |
| 99 | 149 | 249 | 349 | 499 | 749 | 999 | 1,499 | 1,500** | |
| Public space | 75 | 100 | 125 | 125 | 185 | 225 | 250 | 275 | |
| Mgr's office | 200 | 200 | 200 | 200 | 230 | 230 | 230 | 250 | |
| Rental office | 180 | 200 | 225 | 250 | See | ||||
| Asst. mgr's office | 160 | Below | |||||||
| Gen'l work space | 120 | 125 | 200 | 275 | 310 | 500 | 550 | 625 | |
**For these projects, housing authorities shall submit recommendations to the commissioner for prior approval.
| Number of Dwelling Units in Project | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Under | 100 | 150 | 250 | 350 | 500 | 750 | Over | ||
| 99 | 149 | 249 | 349 | 499 | 749 | 999 | 1,000** | ||
| General repair shop | 200 | 300 | 500 | 400 | 500 | 650 | 700 | ||
| Mech. repair shop | 400 | 500 | 650 | 700 | |||||
| Paint shop | 50 | 60 | 150 | 175 | 200 | 250 | 275 | ||
| Stock storage room | 250 | 375 | 525 | 800 | 900 | 1,000 | See | ||
| Superintendent's Office | 100 | 150 | 150 | 200 | 200 | Below | |||
| Locker & toilet facilities | |||||||||
| No. of toilets | 1 | 1 | 1 | 2 | 2 | 3 | 3 | ||
| No. of lavatories | 1 | 1 | 1 | 1 | 2 | 2 | 3 | ||
| No. of showers | 1 | 1 | 1 | 2 | 2 | ||||
**For these projects, housing authorities shall submit recommendations to the commissioner for prior approval.
Note:
In projects with individual heaters the area of the mechanical repair shop may be reduced by one third.
9 NYCRR 1610.3 - Residential buildings
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
9 NYCRR 1610.4 - Dwelling units
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
| No. of bedrooms in apartment | Square foot storage |
|---|---|
| 0 | 20 |
| 1 | 30 |
| 2 | 30 |
| 3 | 30 |
| 4 | 35 |
| 5 | 40 |
| 6 | 45 |
Bedroom closets shall be located within each bedroom, have a clear depth of not less than 22 inches, and be two lineal feet minimum in length per person. However, not more than one bedroom closet may be located in a hall, and not more than five feet from the bedroom door. At least one closet, preferably near the apartment entrance, the coat closet, shall have a clear minimum depth of 22 inches and a clear area of approximately eight square feet and shall have a door with a lock.
Provide the following equipment and spaces:
| 0 bedroom apartment | — 25 square feet |
| 1 ″ ″ | — 30 ″ ″ |
| 2 ″ ″ | — 38 ″ ″ |
| 3 ″ ″ | — 46 ″ ″ |
| 4 ″ ″ | — 55 ″ ″ |
| 5 ″ ″ | — 65 ″ ″ |
Partitions between bathrooms or toilets and living rooms in the same apartment shall be constructed the same as the partition between apartments described below.
Between all dwelling units, sound reduction of at least 40 decibles at an average frequency of 256 to 1024 cycles per second shall be obtained by the use of suitable construction methods and materials. (See National Bureau of Standards Report #BMS 144 on sound insulation of wall and floor constructions, and subsequent revisions or supplements.)
The following requirements, unless waived or modified by the commissioner upon request of an authority shall apply to all windows in buildings three stories or more in height. Projected sash windows which are so designed that there is minimum danger of persons falling out do not require special protective devices or screens. Approved devices shall be installed on hoppers, casements and the lower half of double hung windows which would restrict their opening to not more than four and one-half inches.
In planning dwelling units the essential test is livability, and this will be the basis for review by the division. Unit plans submitted for review must, therefore, show furniture, radiation, exposed pipes, electric outlets and door swings. Minimum furniture shall be spaced so as to permit adequate circulation space, and shall be of the following approximate sizes:
Twin beds or double bed, dresser and chair. Child's crib in principal bedroom.
| Double bed | — 4 feet | 9 inches by | 6 feet | 9 inches |
| Twin bed | — 3 ″ | 6 ″ ″ | 6 ″ | 9 ″ |
| Child's crib | — 2 ″ | 4 ″ ″ | 4 ″ | 5 ″ |
| Dresser | — 1 ″ | 10 ″ ″ | 3 ″ | 6 ″ |
| Chair | — 1 ″ | 6 ″ ″ | 1 ″ | 6 ″ |
| A couch or studio couch | — 6 feet | 9 inches by | 3 feet | 0 inches | |
| Two easy chairs | — 2 ″ | 6 ″ ″ | 3 ″ | 0 ″ | each |
| A desk or table | — 2 ″ | 0 ″ ″ | 3 ″ | 4 ″ | |
| Console radio or TV set | — 2 ″ | 8 ″ ″ | 2 ″ | 0 ″ | |
| and other incidental furniture. | |||||
| Add dresser in living room of zero bedroom apartment. | |||||
Seating and table space for the maximum number of persons the unit will accommodate, must be provided. The clearance around the dining table shall not be less than as follows:
| Table for | 2 people— | 2 feet | 6 inches by | 2 feet | 6 inches | |
| ″ ″ | 4 ″ | 2 ″ | 6 ″ ″ | 3 ″ | 2 ″ | |
| ″ ″ | 5 ″ | 3 ″ | 0 ″ ″ | 4 ″ | 0 ″ | (seating at one end) |
| ″ ″ | 6 ″ | 3 ″ | 0 ″ ″ | 4 ″ | 0 ″ | (seating at both ends) |
| ″ ″ | 6 ″ | 4 ″ | 0 ″ ″ | 4 ″ | 0 ″ | (recommended) |
| ″ ″ | 7 ″ | 3 ″ | 0 ″ ″ | 6 ″ | 0 ″ | (seating at one end) |
| ″ ″ | 8 ″ | 3 ″ | 0 ″ ″ | 6 ″ | 0 ″ | (seating at two ends) |
| ″ ″ | 10 ″ | 3 ″ | 0 ″ ″ | 8 ″ | 0 ″ | (seating at two ends) |
See following table which indicates the minimum net room areas in square feet. These requirements must be adhered to.
Table of Minimum Room Sizes
| Design | No. B.R. | Unit type | L.R. | D.Sp. | Kit. | 1st B.R. | 2nd B.R. | 3rd B.R. | 4th B.R. | 5th B.R. | Con. Rm. Ct. | Rent. Rm. Ct. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | Comb. Living & Sleeping Rm; Kit.,* Dining Sp.** | 170 | 30 | 45 | — | — | — | — | — | 2 | 2½ |
| D | 1 | L.R., Kit., Dining Sp.** 1-2 pers. Bed Room | 165 | 30 | 50 | 130 | — | — | — | — | 3 | 3½ |
| F | 2 | L.R., Kit., Dining Sp.** 2-2 pers. Bed Rooms | 170 | 45 | 55 | 130 | 115 | — | — | — | 4 | 4½ |
| I | 3 | L.R., Kit., Dining Sp.** 3-2 pers. Bed Rooms | 185 | 65 | 60 | 130 | 115 | 115 | — | — | 5 | 5½ |
| K | 4 | L.R., Kit., Dining Sp.** 4-2 pers. Bed Rooms | 195 | 75 | 65 | 130 | 115 | 115 | 115 | — | 6 | 6½ |
| L | 5 | L.R., Kit., Dining Sp.** 5-2 pers. Bed Rooms | 200 | 85 | 70 | 130 | 115 | 115 | 115 | 115 | 7 | 7½ |
* Omit space for clothes washing machine in A.
** Dining space may be in living room or kitchen.