9 NYCRR 1506.1 - General requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Motor vehicle storage facilities provided pursuant to section 136 of chapter 61-B of the Consolidated Laws (Multiple Residence Law) of the State of New York, shall conform to the regulations as set forth herein, entitled Part 1506, Motor Vehicle Storage in New Multiple Dwellings or Upon the Premises Thereof.
(b)Motor vehicle storage facilities in a multiple dwelling or in a structure upon the premises thereof shall be separated from the multiple dwelling by distance, or by fire-resistive materials and construction, to retard the spread of fire from within such facilities, and shall be equipped so as not to be a hazard to the safety and health of occupants of the multiple dwelling.
(c)Such motor vehicle storage facilities shall be arranged and constructed so that flammable vapors cannot spread to fixed sources of ignition; so that toxic gases and flammable vapors originating within such facilities cannot spread to the multiple dwelling; so that air for heating, ventilation and such uses cannot be circulated from such facilities to the multiple dwelling. The floors of such facilities shall be of materials that will not absorb flammable liquids nor be ignitable, and each floor shall slope to a floor drain equipped with an oil separator. Such oil separator shall be properly maintained.
(d)Motor vehicle storage facilities in or attached to a multiple dwelling shall be separated from such dwelling by construction having a fire resistance rating commensurate with the fire hazard involved. Such construction shall be continuous and unpierced by openings; except that openings shall be permitted therein when equipped with self-closing opening protectives having a fire resistance rating commensurate with the fire resistance rating of the separating construction, and when constructed in accordance with the requirements of this Part.
(e)Roof storage.

When motor vehicle storage facilities are provided on a roof, such roof shall be designed and constructed to support the resulting load; if such roof be the roof of a multiple dwelling, such dwelling shall be of fireproof construction.

(f)Roof storage parapet wall.

Roofs used for the storage of motor vehicles shall be provided with a noncombustible parapet wall at least 24 inches high. Such wall shall be designed to resist a lateral horizontal force of 300 pounds per linear foot, applied 21 inches above the level of the roof. If a substantial eight-inch high curb is provided at least four feet from the parapet wall, such wall need only be designed to resist a lateral horizontal force of 150 pounds per linear foot. When the parapet wall is less than 42 inches high, a railing capable of resisting a lateral horizontal force of 100 pounds per linear foot applied at the top rail shall be attached thereto. Such railing shall have a height of at least 42 inches above the roof level and any opening therein shall not exceed eight inches in at least one dimension.

(g)Parking decks and open sides.

Where a side of a motor vehicle storage facility is not enclosed, such side shall be protected with a noncombustible wall at each floor level at least 24 inches in height. Such wall shall be designed to resist a lateral horizontal force of 300 pounds per linear foot, applied 21 inches above the floor level. When an eight-inch curb is provided at least four feet from the wall, such wall need only be designed to resist a lateral force of 150 pounds per linear foot. When the height of such wall above the floor level is less than 42 inches, a railing capable of resisting a lateral horizontal force of 100 pounds per linear foot applied at the top rail shall be attached thereto. Such railing shall have a height of at least 42 inches above the floor level and any opening therein shall not exceed eight inches in width and four feet in length.

(h)Open storage.

Motor vehicles stored in the open upon the premises of a multiple dwelling shall not be stored within five feet of a combustible wall or wall opening of that multiple dwelling, except when such wall is protected to a height of at least eight feet on the side nearest such storage by a noncombustible facing of at least three-quarter hour fire protection, and such openings are equipped with opening protectives having a fire resistance rating of at least three-quarter hour.

9 NYCRR 1506.2 - Height and area requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Motor vehicle storage facilities in multiple dwellings.

Facilities for storage of motor vehicles in any multiple dwelling may be of unlimited height and area except that the total area of all stories including any extensions beyond the perimeter of the multiple dwelling shall not exceed that required for one vehicle for each apartment or suite of rooms with at least 200 square feet of floor area allowed for each vehicle.

(b)Motor vehicle storage facilities upon the same premises with a multiple dwelling.
(1)The height and area of motor vehicle storage facilities in a building upon the premises of a multiple dwelling shall meet the requirements set forth in Table 1.

TABLE 1

Height and Area Requirements of Motor Vehicle Storage Facilities in a Building Upon the Premises of a Multiple Dwelling

Maximum height1
Type of constructionMinimum fire resistance of floors in hoursin storiesin feetMaximum area per floor in square feet
Fireproof3UnlimitedUnlimited
Fireproof267520,000
Protected noncombustible1½56512,000
Protected noncombustible¾4509,500
Heavy timber (mill)¾4509,500
Ordinary¾2306,500
Unprotected noncombustible—2306,500
Wood frame¾1205,000

1

Where a motor vehicle storage facility is equipped with an automatic sprinkler system the figures in the height columns may be increased by one story and 12 feet respectively.

(2)The permissible floor area of motor vehicle storage facilities with frontages of more than 25 per cent of the building perimeter on one or more streets, or other accessible legal open space at least 30 feet wide, may be increased two per cent for each one per cent of such frontage in excess, of 25 per cent.

9 NYCRR 1506.3 - Motor vehicle service facilities

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Space within motor vehicle storage facilities in multiple dwellings shall not contain volatile flammable solvents, nor facilities for oil or grease handling, service, or repair, except that vehicle cleaning and washing shall be permitted.
(b)Space within motor vehicle storage facilities upon the premises of any multiple dwelling shall not contain volatile flammable solvents, or facilities for oil or grease handling, except on the ground floor or roof, and provided that such service facilities shall comply with generally accepted safety standards.

9 NYCRR 1506.4 - Separation requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)The walls enclosing motor vehicle storage facilities in a multiple dwelling, the structural members therein and the floor over and the floor below the storage facilities shall be of noncombustible construction having fire resistance ratings of at least two hours but not less than that required for the corresponding components of the multiple dwelling.
(b)The common wall between a multiple dwelling and an attached building or structure for motor vehicle storage shall be of noncombustible materials and have a fire resistance rating of at least two hours. All portions of such building or structure that are less than 10 feet from the multiple dwelling shall be of noncombustible materials and have a fire resistance rating of at least two hours, except that nonbearing walls other than the common wall and bearing walls that are more than 10 feet but within 20 feet from the multiple dwelling shall have a fire resistance rating of not less than three-quarter hour.
(c)Motor vehicle storage facilities having an above-grade building volume exceeding 8000 cubic feet or exceeding one story in height and having exterior walls less than 20 feet from a multiple dwelling, shall have such walls protected on the exterior with noncombustible facings of at least three-quarter hour fire protection, but the fire resistance rating of such walls shall be not less than that required for the type of construction of such facility.

9 NYCRR 1506.5 - Openings and opening protectives

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Openings in separating walls for passage between multiple dwellings and motor vehicle storage facilities in or attached to a multiple dwelling shall be provided with vestibules not less than six feet long and of noncombustible construction having a fire resistance rating of not less than two hours and equipped with self-closing doors having a fire resistance rating of not less than one and one-half hours. Such fire-resistive doors may be provided with a vision panel of wired glass of not more than 100 square inches in area with no dimension exceeding 12 inches.
(b)When a motor vehicle storage facility is not within the enclosing walls of a multiple dwelling but is connected thereto by an enclosed passageway, the requirements of subdivision (a) above for communicating openings between a motor vehicle storage facility and a multiple dwelling shall apply.
(c)Openings for vehicles shall be directly from the outside of the building and shall be located not less than 20 feet from any door of the multiple dwelling and shall be at least seven feet in width. Other openings in exterior walls of motor vehicle storage facilities in multiple dwellings and openings less than 20 feet from a multiple dwelling and in exterior walls of such storage facility upon the same premises with a multiple dwelling, shall be equipped with opening protectives having a fire resistance rating of at least three-quarter hour.
(d)Where a motor vehicle storage facility is on the same premises with a multiple dwelling, and there are openings in the walls of such multiple dwelling that are less than 30 feet above and less than 20 feet horizontally from the roof of the motor vehicle storage facility, such openings shall be protected by three-quarter hour opening protectives, or, in lieu thereof, the roof of such facility shall be of noncombustible construction having a fire resistance rating of at least three-quarter hour.

9 NYCRR 1506.6 - Exit requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)There shall be provided from every floor of motor vehicle storage facilities in a multiple dwelling or upon the premises thereof at least two means of egress located remote from each other. Such means of egress shall lead directly, or through an exit passageway or an exit stairway in a two-hour fire-resistive enclosure, to a legal open space having access to a street. Exits, exit passageways and exit stairways shall be at least 36 inches wide and six feet six inches high. Ramps used shall have a slope not to exceed one foot in 10 feet and shall be provided with nonslip surfaces. The maximum distance of travel to an exit or exitway shall not exceed 100 feet, except that such distance may be 150 feet when the storage facility is equipped with an automatic sprinkler system. A ramp for vehicles may be considered as one means of egress when such ramp is remote from the main enclosed exit and when it has a terminus at grade within 50 feet of an exit door opening to the exterior.
(b)All exit doors shall be self-closing and swing in the direction of egress. Interior exit doors shall have a fire resistance rating of at least one and one-half hours. Exterior exit doors shall have a fire resistance rating of at least three-quarter hour. Where doors swing into the path of travel from other areas, they shall be so located as not to project into such path of travel. Doors to stairways shall open upon a landing providing a distance from door swing to line of tread of stairs not less than the width of the doors. Louvers are not permitted in interior exit doors.
(c)All doors used as required exits shall be arranged so as to be readily openable from the motor vehicle storage facility side. Locks, if provided on required exits, shall not require a key to be operated from the motor vehicle storage facility side.
(d)Every enclosed stairway shall have at its topmost landing an opening to the exterior at least 24 by 30 inches, provided with a window or door, readily accessible and easily openable from both the interior and exterior of the building.
(e)Stairs shall be constructed of noncombustible materials, shall provide for safe ascent and descent. The use of winders shall not be permitted. Stairs shall be at least three feet in clear width throughout and have a handrail on the open side or, if enclosed, on at least one side, with a clearance of at least one and one-half inches between the handrail and the wall and placed at least 31 inches above the center of the tread; when three feet eight inches or more in width, handrails shall be provided on each side. Treads, exclusive of nosing, shall be not less than nine and one-half inches wide; risers shall not exceed seven and three-quarter inches in height; and the product of the number of inches in width of the tread and the number of inches in the height of the riser shall be at least 70 and at most 75. Minimum headroom shall be six feet six inches measured vertically from the surface of the tread at the nosing.
(f)Well openings and window openings on stairs, ramps or landings shall be guarded by substantial railings at least 33 inches high above the floor or tread level. The openings in such railings shall not exceed six inches in width nor 48 inches in length.
(g)Exitways shall be lighted by natural and, or artificial light of sufficient intensity to allow safe passage at all times.
(h)Every means of egress shall be indicated by a durable sign reading EXIT in red letters at least eight inches high on a white background or vice versa, and such sign shall be clearly visible at all times.

9 NYCRR 1506.7 - Ventilation

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021

Motor vehicle storage facilities in a multiple dwelling or upon the premises thereof shall be provided with natural or mechanical ventilation capable of preventing the accumulation of flammable gases or vapors. Where such facilities do not have natural ventilation they shall have mechanical ventilation providing not less than six complete changes of air per hour at all times during occupancy of the garage. Where such facilities are located above grade, every room or space therein shall be provided with openings to the outer air, having a combined area of not less than two per cent of the floor area; or such rooms or space shall have mechanical ventilation providing six air changes per hour.

9 NYCRR 1506.8 - Structural requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Constructions and parts thereof used for the storage of motor vehicles in a multiple dwelling or upon the premises thereof shall be capable of sustaining safely the loads to which they are subject. The motor vehicle loads on floors, roofs, and ramps shall be those set by the department but in no case shall they be less than a uniformly distributed load of 75 pounds per square foot, or 2,000 pounds concentrated on an area nine inches in diameter, whichever produces the greater stress.
(b)Wherever structural material or assemblies of such construction may, if unprotected, deteriorate and become structurally unsound under the proposed conditions of use, approved protection shall be provided. Causes of such deterioration include, among others, action of freezing and thawing, dampness, wetting and drying, termites and rodents.
(c)Parts of such buildings built in soil which is water bearing at any season of the year shall be constructed so that ground water will not flow into basements and cellars.

9 NYCRR 1506.9 - Equipment requirements

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)General.

The construction, installation, operation, and maintenance of equipment in motor vehicle storage facilities, except as otherwise specified in this Part, shall be in accordance with the generally accepted standards listed in the appendix*.

(b)Plumbing.

Plumbing systems shall be designed and installed to supply water and to convey waste in a manner free from health and physical hazards.

(c)Gas piping.
(1)Gas piping systems shall be designed and installed so as to be free from health and physical hazards under normal conditions of use.
(2)Gas piping systems shall provide a supply of gas sufficient to meet the maximum expected demand of the installed gas-burning appliances, shall be of materials resistant to the corrosive effect of gases conveyed, and shall remain, with a minimum of maintenance, gastight, safe, frost-free, and operative under conditions of use.
(3)Gas piping systems shall have a valve in an accessible location outside the building for shutting off all gas to the system.
(d)Heating.
(1)Heating facilities shall be designed and installed in a manner free from fire, health, and physical hazards under conditions of use.
(2)Heat producing equipment shall not be operated beyond the safe capacity for which it has been designed.
(3)Heat producing equipment, other than direct-fired unit heaters installed eight feet or more above the floor level, shall be located in separate buildings or in rooms enclosed by solid and vaportight noncombustible construction. Such rooms shall be separated from other parts of the building with constructions having fire resistance rating of at least two hours. Separating constructions shall be unpierced except where necessary for the passage of heating pipes or ducts. Openings around such pipes and ducts shall be sealed with masonry or other noncombustible material. Entrance to such rooms shall be from the outside of the building.
(4)Flue and gasvent outlets shall be located so as not to be lower than the level of the top of any window or other exterior wall opening which is less than 15 feet horizontally or 30 feet vertically from the outlet, nor shall such outlets be less than two feet above the level of any unprotected combustible part of any building or construction when such part is 10 feet or less from the outlet.
(e)Electrical wiring and equipment.

Electrical wiring and equipment shall be designed and installed so as not to be a potential source of ignition of combustible material or become a potential source of electrical hazard.

(f)Lighting.

Facilities for the storage of motor vehicles and private thoroughfares leading thereto shall be wired for electricity, and light outlets and fixtures shall be installed to provide adequate lighting.

(g)Elevators and hoisting equipment.
(1)Elevators and hoisting equipment shall be designed and installed so as to perform their functions in a manner free from physical and fire hazards.
(2)Elevator hoistways shall be enclosed in constructions having a fire resistance rating of at least two hours, except that in motor vehicle storage facilities not more than two stories in height the elevator hoistway enclosure on above-grade floors may be of unprotected noncombustible material. Door openings in hoistways in two-hour fire-resistive enclosures shall be provided with fire doors or opening protectives having a fire resistance rating of at least one and one-half hours.
(h)Fire-extinguishing equipment.
(1)Sprinkler systems.
(i)Where motor vehicle storage facilities are located in a multiple dwelling and have a capacity of 20 or more vehicles, an automatic sprinkler system shall be installed in such facilities in conformity with the requirements entitled Part 1503, Sprinkler Systems in Hotels and Similar Dwellings.
(ii)When motor vehicle storage facilities are located in a basement or cellar of a building upon the premises of a multiple dwelling, and such storage facility has a capacity of 20 or more vehicles, an automatic sprinkler system shall be installed in such basement or cellar in conformity with the requirements entitled Part 1503, Sprinkler Systems in Hotels and Similar Dwellings.
(iii)When approved by the department, a tank supplying a standpipe system may be used to supply the sprinkler system.
(2)Standpipes.
(i)Motor vehicle storage facilities in a multiple dwelling or upon the premises thereof which are more than two stories or 30 feet in height or which have a floor area above the grade floor exceeding 10,000 square feet per floor shall be equipped with standpipes not less than two and one-half inches in diameter, unless:
(a)such facilities are more than four stories or 50 feet in height, in which event the premises shall be equipped with standpipes not less than four inches in diameter; or
(b)such facilities are more than six stories or 75 feet in height, in which event the said premises shall be equipped with standpipes not less than six inches in diameter.
(ii)No standpipes shall be required when such facilities are equipped with a sprinkler system installed pursuant to the requirements entitled Part 1503, Sprinkler Systems in Hotels and Similar Dwellings.
(iii)Standpipes required by this Part shall conform to approved standards, and shall be of such number and so located that all parts of each floor can be reached by a 30-foot stream from a nozzle attached to 100 feet of hose connected to the riser and outlet on that floor.
(iv)Standpipes shall be equipped with fire department outlets on every floor.
(v)Standpipes shall be equipped with outlets and first-aid hose in conformity with the regulations set forth in subparagraph (ii) of paragraph (3) of this subdivision.
(vi)Standpipes shall be protected from freezing and damage.
(vii)Standpipes shall be equipped with approved fire department inlet connections. The number of such fire department connections shall be determined by the department having jurisdiction. Fire department inlet connections shall be constructed of corrosion-resistive metal, located on a street front of the building or structure not less than 18 inches or more than 36 inches above grade, and when located more than two feet above grade, shall not project beyond the building face. Such connections shall be marked with raised letters not less than one inch in height reading: TO STANDPIPE; or identified otherwise for type of standpipe.
(viii)Standpipe systems shall be supplied with water in conformity with generally accepted standards listed in the appendix to this Part* to the extent that such standards are consistent with this Part.
(ix)When approved by the department, a tank supplying a domestic water system or a sprinkler system may be used to supply the standpipe system.
(3)First-aid fire equipment.
(i)Motor vehicle storage facilities in a multiple dwelling or upon the premises thereof shall be equipped with manual fire extinguishing equipment of a type suitable for the occupancy and shall be so located and installed as to be visible and readily accessible. There shall be at least one such fire extinguisher located in each 4,000 square feet of floor area or fraction thereof.
(ii)Motor vehicle storage facilities in a multiple dwelling or upon the premises thereof shall be equipped with standpipe outlets and first-aid fire hose on every floor when standpipes are required by this Part, except when such facilities are equipped with an automatic sprinkler system. Such outlets and hose shall be in conformity with generally accepted standards and shall be located in or near stairways or exitways.
(iii)First-aid fire equipment shall be maintained in good operating condition at all times.

9 NYCRR 1506.10 - Maintenance

Later State Register activity may affect this section.

Top
Dates and status
NYCRR title agency
Executive Department
Section status
Section source receipt
Source version current through
Sep 15, 2021
(a)Open containers of volatile flammable liquids shall be prohibited in motor vehicle storage facilities.
(b)Smoking shall be prohibited in motor vehicle storage facilities, and conspicuous durable signs to this effect shall be displayed therein at all times.

Back to top