9 NYCRR 1505.1 - General requirements
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Fire escapes on old multiple dwellings, on hotels and similar dwellings, and on nonfireproof new multiple dwellings, installed pursuant to chapter 61-B of the Consolidated Laws (Multiple Residence Law) of the State of New York, shall conform to the regulations as set forth herein, entitled Part 1505, Fire Escape Systems.
9 NYCRR 1505.2 - Terminus of fire escapes
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
All required fire escapes shall lead to the street, or to a yard, court, area or passageway affording continuous, safe and unobstructed access to a street.
9 NYCRR 1505.3 - Fire escapes supplemental to a required means of egress
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Wire, chain, cable, rope fire escapes, vertical ladder and other fire escapes, supplemental to a required means of egress shall be maintained in good order and repair, and be structurally safe and free of obstruction.
9 NYCRR 1505.4 - Fire escapes on old multiple dwellings permitted as a second means of egress
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Fire escapes installed on old multiple dwellings prior to July 1, 1953, and permitted as a second means of egress, shall conform to the following rules and regulations: (see § 1505.5 below for requirements governing such fire escapes installed on old multiple dwellings on and after July 1, 1953).
Balconies shall be accessible from the interior space through a clear opening whose minimum dimensions are two feet wide and two feet six inches high.
Such fire escapes shall be maintained in good order and repair, and be structurally safe and kept free of obstruction.
9 NYCRR 1505.5 - New fire escapes
Later State Register activity may affect this section.
Dates and status
- NYCRR title agency
- Executive Department
- Section status
- Section source receipt
- Source version current through
- Sep 15, 2021
Such fire escapes shall comply with the provisions of section 133 of chapter 61-B of the Consolidated Laws (Multiple Residence Law) of the State of New York, and shall be constructed, installed, arranged and maintained in accordance with the following rules and regulations:
All doors and windows affording direct access to fire escapes shall open upon a balcony platform. The bottom of the openable window providing access to the balcony shall be not more than 18 inches, nor less than seven inches above the balcony platform. Sills of doors affording access to fire escapes shall be not more than eight inches nor less than four inches above the balcony platform.