Section 382-a of the Executive Law provides that commercial and industrial buildings and structures that utilize truss type construction shall be marked by a sign or symbol that informs persons conducting fire control and other emergency operations of the existence of truss construction. Section 382-a further directs the State Fire Prevention and Building Code Council to promulgate rules and regulations it deems necessary to carry into effect the provisions of the statute. This Part establishes certain requirements pertaining to the identification of buildings and structures that utilize truss type construction.
19 NYCRR 1264.2 - Enforcement
Compiled source label: current through Jun 30, 2022
Register checked through July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08) - no later Register activity found for this section
What LawEngine checked
- Status
- Source receipt
- Compiled source current through
- Jun 30, 2022
- Register checked through
- July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08)
- Register activity status
- no later Register activity found
- LawEngine source snapshot
- Jun 6, 2026
19 NYCRR 1264.3 - Definition
Compiled source label: current through Jun 30, 2022
Register checked through July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08) - no later Register activity found for this section
What LawEngine checked
- Status
- Source receipt
- Compiled source current through
- Jun 30, 2022
- Register checked through
- July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08)
- Register activity status
- no later Register activity found
- LawEngine source snapshot
- Jun 6, 2026
For the purposes of this Part, truss type construction shall mean a fabricated structure of wood or steel, made up of a series of members connected at their ends to form a series of triangles to span a distance greater than would be possible with any of the individual members on their own. Truss type construction shall not include:
19 NYCRR 1264.4 - Identification of truss type construction
Compiled source label: current through Jun 30, 2022
Register checked through July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08) - Register activity found; review before filing
What LawEngine checked
- Status
- Later rule activity found; update pending
- Compiled source current through
- Jun 30, 2022
- Register checked through
- July 8, 2026/Vol. XLVIII, Issue 27 (2026-07-08)
- Register activity status
- Register activity found; review before filing
- Latest notice
- DOS-11-25-00002-A
- Latest notice date
- Dec 24, 2025
- LawEngine source snapshot
- Jun 6, 2026
Cornell body matches LawEngine but is not current to the latest scoped Register action.
"F" shall mean floor framing, including girders and beams "R" shall mean roof framing "FR" shall mean floor and roof framing The construction type designation shall be placed at the 12 o'clock position over the structural component designation, which shall be placed at the six o'clock position.
TRUSS IDENTIFICATION SIGN LOCATIONS Sign location Sign placement Exterior building entrance doors, exterior exit discharge doors, and exterior roof access doors to a stairway Attached to the door, or attached to a sidelight or the face of the building, not more than 12 inches (305 mm) horizontally from the latch side of the door jamb, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface Multiple contiguous exterior building entrance or exit discharge doors Attached at each end of the row of doors and at a maximum horizontal distance of 12 feet (3.65 m) between signs, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface Fire department hose connections Attached to the face of the building, not more than 12 inches (305 mm) horizontally from the center line of the fire department hose connection, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface